You are here:Home » Q & A

How to Solve the Problem of Too Slow Operation or Too Low Vibration Power of Pneumatic Vibrator

Time:2018-11-30

1. New installation:
 
 
1. The surface of the pneumatic vibrator to be installed must be flat. Normally, there is no case that the pneumatic vibrator runs too slowly or the vibration power is too low.
 
 
2. Adjust the pressure regulator to increase the speed of the vibrator.
 
 
3. Check whether the air supply pipe is connected to the intake or exhaust port (marked by arrows).
 
 
4. Check whether the hose is bent.
 
 
5. Check whether the diameter of the air supply pipe is large enough or too long. Also check the size of the valve used.
 
 
6. Check whether there are too many gas-consuming components connected to the same gas supply pipe at the same time. Gas-consuming components should be selectively opened.
 
 
Two, installed:
 
 
1. Remove the muffler or exhaust pipe. If the vibrator works properly without them, the muffler or exhaust pipe may be blocked by dust. Clean or replace with gasoline (or kerosene).
 
 
2. Check whether there is dust accumulation in the online filter, whether there is rust in the supply pipe, and the friar particles may block the filter.
 
 
3. Check whether there is leakage in the air supply pipe and confirm that the air compressor can work normally. Check whether the hose is bent.
 
 
4. The lubricating oil of the vibrator will stick. Add a few drops of gasoline (or kerosene) from the intake to remove the bond.
 
 
5. Check whether the vibrator has accumulated dust. If yes, clean with gasoline (or kerosene).